In this paper, a performance comparison between PC-based data acquisition systems is carried out with reference to their immunity to electromagnetic conducted disturbances. The aim is to identify suitable measurement procedures at present not available both in the literature and in EMC standards. The data acquisition system (personal computer and data acquisition board) is approached as a whole system and subjected to the more relevant conducted interference considered by EN standards, electrical fast transient and noise by conducted radio frequency field. Experimental tests, carried out in a shielded environment, highlight the relevance of a specific EMI characterisation of this apparatus.
Event details
- Event
- XVII IMEKO World Congress
- Place
- Dubrovnik, CROATIA
- Time
- 22 June 2003 - 28 June 2003
- Website
- http://www.hmd.hr/imeko/