Skip to main content

TRACEABLE CALIBRATION OF POWER HARMONICS AND FLICKER ANALYSERS

Greg Hammond, Ilya Budovsky

Abstract

The paper describes a precision measurement system developed at NML for the calibration of three-phase instruments measuring harmonics of current up to 16 A, voltage fluctuation and flicker. Particular attention is given to establishing a traceable link to the Australian primary standards of electrical quantities. Current and voltage harmonics up to the 99<sup>th</sup> and fluctuating voltages can be generated and measured with relative uncertainties close to 1·10<sup>-5</sup>.

Keywords
harmonics, flicker, standards
Download
PWC-2003-TC4-010.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
XVII IMEKO World Congress
Place
Dubrovnik, CROATIA
Time
22 June 2003 - 28 June 2003
Website
http://www.hmd.hr/imeko/

Back to the proceedings