Abstract

In recent years the problem of harmonic pollution has become more urgent, because of the development in distribution systems of non linear loads that draw non-sinusoidal currents. This paper presents a time domain method for harmonics sources detection in power systems, which can be usefully applied also in presence of unbalance or asymmetry. Harmonic power flows are calculated in real time and no spectral analysis is required for the evaluation of currents amplitudes and phase angles. The development of a new instrument is described, which is able to measure several network power quality parameters; measurement accuracy is estimated and experimental results are reported.

Keywords
harmonics, unbalance, harmonics sources
Download
PWC-2003-TC4-015.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities