Skip to main content

Statistical Analysis of 2 MN and 4 MN Force Range Key Comparisons

T. Bartel

Abstract

The factors contributing to the uncertainty are discussed for the measurements that were conducted for the 2 MN and 4 MN force values of the very high force key comparison administered by the Comité International des Poids et Mesures (CIPM). Details of the statistical analysis by the pilot institute, NIST, are provided. Various options for calculating the reference values and degrees of equivalence are presented, accounting for the uncertainty differences associated with the comparison force transfer standards and with the force standard machines of the participating National Metrology Institutes (NMI).

Keywords
degrees of equivalence, force, force standard, key comparison, metrology, reference value, transfer standard, uncertainty
Download
IMEKO-TC3-2007-060u.pdf
DOI
-
IMEKO TC
TC3 - Measurement of Force, Mass, Torque, and Gravity

Event details

Event
Cultivating Metrological Knowledge
Linked User
Dirk Röske
Technical Committee
TC3
Place
Merida, MEXICO
Time
27 November 2007 - 1 December 2007
Website
http://www.cenam.mx/fyp/imeko2.html

Back to the proceedings