Skip to main content

About the power standards calibration in the National Institute of Metrology, Romania

Ioana Odor, Dorin Flaminzeanu, Cornel Baltateanu, Dan Mihai Stefanescu

Abstract

The paper presents the way in which the Electrical Laboratory from the Romanian Bureau of Legal Metrology – National Institute of Metrology is managing all its capabilities to assure the traceability to SI for the references for electrical power and energy from the utilities and from the manufacturers of watt-hour-meters. The activity described in this paper is performed by using digital equipments, as well as a very accurate analogical power converter, in accordance with the international recognized methods (IEC, IEEE, EA) for calibrating power and energy meters. Till 2006, this activity of calibration was performed only for sinusoidal conditions, following documented procedures and established uncertainty budget under the quality system of the National Institute of Metrology, Romania. So, the laboratory declared the CMCs for AC power single phase and three phases in the Appendix C of The BIPM key comparison database phase. During the last year, for the first time in Romania, new activities are developed for the calibration of power standards and energy meters under non-sinusoidal conditions, and some of them are present in this paper.

Download
IMEKO-TC4-2007-077.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
TC4 Symposium 2007
Technical Committee
TC4
Place
Iasi, ROMANIA
Download
TC4CallForPapers.pdf
Time
19 September 2007 - 21 September 2007
Website
http://www.imeko2007.ee.tuiasi.ro/

Back to the proceedings