Skip to main content

APPLICATION ON MEASUREMENT OF PRE-STRESS LOSS IN CONCRETE STRUCTURE WITH FIBER-OPTIC SENSORS

Tang Hongwei, Li Wansheng, Li Yuhong

Abstract

As one of the important works in the pre-stressed concrete structure design, magnitude of the pre-stress loss has not been measured conveniently until now. A suitable measuring technique for pre-stress loss is the studying goal of researcher in a long time. In the present work, the fiber-optic measuring technique has been introduced to measure the pre-stress loss, and all of the measuring works were conducted on the model of a wastewater tank. Result of the measurement shows that optical fiber sensor can be used to measure the pre-stress loss in engineering, and the short-term pre-stress loss of steel strand is strongly effected by the arranging manner of steel strand, the magnitude of pre-stress loss measured in the present work is less than 20%.

Keywords
fiber-optic sensor, pre-stress loss, concrete structure
Download
IMEKO-TC20-2002-007.pdf
DOI
-
IMEKO TC
TC20 - Measurements of Energy and Related Quantities

Event details

Event
Joint International Conference on Force, Mass, Torque, Hardness and Civil Engineering Metrology in the age of globalization
Technical Committee
TC20
Place
Celle, GERMANY
Time
24 September 2002 - 26 September 2002

Back to the proceedings