Skip to main content

THE EFFECT OF ADJUSTMENT ON MULTIFUNCTION INSTRUMENTS FOR ELECTRICAL METROLOGY: CASE EXAMPLES

Giuseppe La Paglia, Gian Carlo Bosco, Marco Lanzillotti,  Luca Callegaro

Abstract

Top-class multifunction instruments (multimeters and calibrators) implement in their firmware adjustment procedures requiring a minimal set of adjustment standards. The small set of standards' values provided have effects on the (usually very broad) ranges of values and frequencies which the instrument can measure. How errors and uncertainties in the adjustment of specific points affect measurements in such broad ranges has been experimentally investigated in top-class multimeters and calibrators; most interesting results have been observed in the ‘ac voltage’ function; a number of examples are reported.

Download
IMEKO-TC4-2008-055.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
Exploring New Frontiers of Instrumentation and Methods for Electrical and Electronic Measurements
Technical Committee
TC4
Place
Florence, ITALY
Time
22 September 2008 - 24 September 2008
Website
http://www.imeko2008.org/