Skip to main content

ESTABLISHMENT OF AN AUTOMATED 10 V JOSEPHSON SERIES ARRAY VOLTAGE STANDARDAT NATIONAL PHYSICAL LABORATORY, INDIA

V. N. Ojha, Shiv Kumar Jaiswal and Sudhir Kumar Sharma

Abstract

In the present paper, we discuss the integration, characterization and operation of the recently established an automated 10 volt Josephson Series Array Voltage Standard (JSAVS) at National Physical Laboratory, India (NPLI). Furthermore, we discuss the precision calibration of the Zener reference standard alongwith the uncertainty budget. The combined standard uncertainty of the Zener reference standard calibration at 10V for a Single Point Measurement (SPM) [1] is ± 25 nV at k=1.

Download
IMEKO-TC4-2008-068.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
Exploring New Frontiers of Instrumentation and Methods for Electrical and Electronic Measurements
Technical Committee
TC4
Place
Florence, ITALY
Time
22 September 2008 - 24 September 2008
Website
http://www.imeko2008.org/

Back to the proceedings