Skip to main content

EASY ESTIMATION OF SPECTRAL PURITY OF TEST SIGNALS FOR ADC TESTING

David Slepička

Abstract

ADC testing frequently confronts the problem of spectral purity of harmonic test signal. The majority of dynamic ADC test methods require test signal distortion at least 10 dB less than that of the tested ADC – the condition that cannot be practically fulfilled for testing up-to-date ADCs. More sophisticated approach to ADC testing applies the correction for test signal imperfections. In both cases test signal distortion has to be known – roughly in the first case and quite accurately in the second case. In this paper an easy method for the testing of signal spectral purity is proposed. Test signal passed by one of two simple analog filters is measured by a common ADC, whose nonlinearity is mathematically post-corrected. The results are compared with common approach applying notch filter and uncertainty analysis is performed.

Download
IMEKO-IWADC-2008-080.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
IWADC 2008
Technical Committee
TC4
Place
Florence, ITALY
Time
22 September 2008 - 24 September 2008
Website
http://www.imeko2008.org/

Back to the proceedings