Skip to main content

DETERMINATION OF SOUND CAUSED BY COMPRESSOR VALVES USING TIME SIGNAL ANALYSIS

Peter Kral, Harald Hackl

Abstract

The measurement of sound levels of noise sources located very closely together – for example the inlet and outlet valve of a piston compressor – is a difficult task. This paper describes a method to evaluate the emitted noise levels of each valve. To achieve precise results, an analysis of the sound pressure level depending on time (time-signal) was done. Signal processing and computations of the measurement results lead to clearer separation of the sound emitted by each sound source (valve).

Keywords
noise measurement, time signal, sound intensity
Download
PWC-2003-TC4-092.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
XVII IMEKO World Congress
Place
Dubrovnik, CROATIA
Time
22 June 2003 - 28 June 2003
Website
http://www.hmd.hr/imeko/

Back to the proceedings