Skip to main content

CONDUCTIVITY MEASUREMENTS AND INTERPRETATIONS REGARDING ANTISTATIC MATERIALS

Peris G. Halaris, Constantinos G. Karagiannopoulos, Perikles D. Bourkas

Abstract

In this work, measurements are given of ohmic resistances in samples of fitted anti-static flooring. The measurement procedures were based on the relevant regulations DIN 51953 and DIN 53482. The measurement values that are shown concern various types of aged anti-static flooring that is commonly found and used in intensive care facilities such as operating theatres, extra care treatment rooms, areas with Computer Tomography systems, etc. Furthermore it presents measurements of new types of anti-static flooring for reasons of comparison. All results are presented in table form and are analysed in detail. The results of all the measurements of this exercise taken into consideration, an attempt is also made to interpret the phenomena that lead to the reduction of conductivity in these materials, and subsequently how these phenomena can be prevented.

Download
IMEKO-TC4-2004-072.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
TC4 Symposium 2004
Technical Committee
TC4
Email
imeko@mail.ntua.gr
Place
Athens, GREECE
Download
imeko_tc4_2004_call_for_papers2.pdf
Time
29 September 2004 - 1 October 2004
Website
http://www.medialab.ntua.gr/IMEKO

Back to the proceedings