LOW COST DEVICE FOR LIGHT FLICKER MEASUREMENT
Abstract
A new instrument for the evaluation of disturbances caused by variations in lamp voltage (light flicker) is proposed, based on light intensity measurements. Unlike current standard (IEC EN 61000-4-15), which determines flicker severity by filtering powering voltage measurements with a standard lamp model (230V/60W), the presented methodology includes the lamp itself in the measurement process, thus realizing an objective measurement of flicker. A testing station for the metrological characterization of the device has been implemented and measurements have been compared to a standard IEC flickermeter (Norma D6000). Thanks to its portability, the instrument can be used to measure light flicker over a wide range of environments spanning from home/office to industrial locations.
Event details
- Event
- TC4 Symposium 2004
- Technical Committee
- TC4
- imeko@mail.ntua.gr
- Place
- Athens, GREECE
- Download
- imeko_tc4_2004_call_for_papers2.pdf
- Time
- 29 September 2004 - 1 October 2004
- Website
- http://www.medialab.ntua.gr/IMEKO