Skip to main content

IMPROVEMENT OF STEP-GAUSS ADC STOCHASTIC TEST METHOD

Jan Holub, Josef Vedral, Miroslav Kubín

Abstract

Improvement of Analog-to-Digital Converters testing method that is suitable for testing of high-resolution AD converters (e.g. Σ-Δ or dither-based) or on the contrary ultra high-speed AD converters is presented. The method is based on the histogram test driven by stochastic signal with defined probability density function. By repeating of the test for different settings of band-pass filter that is inserted to the input testing signal path it is possible to obtain an estimation of frequency dependency of effective number of bits. The results have to be recalculated to equivalent band-pass filtering. Practical demonstration confirmed wider applicability than for direct band-pass filter application.

Keywords
ENOB, ADC, stochastic signal
Download
IMEKO-TC4-2002-006.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
TC4 Conference and Workshop 2002
Technical Committee
TC4
Place
Prague, CZECH REPUBLIC
Time
26 June 2002 - 28 June 2002

Back to the proceedings