A PRECISION CALIBRATION SET-UP FOR AC MAGNETIC FLUX DENSITY MEASUREMENT IN THE RANGE OF 1 Hz TO 20 kHz
Abstract
A precision generating and measurement system of AC magnetic flux density was developed by using a linear low-frequency AC magnetic field converter, a quartz Helmholtz coil, a voltage comparator, a multimeter, a standard resistor, and a computer with a program for automatic measurement. The expanded uncertainty (<i>k</i> = 2) of the calibration system is less than 0.2 % over the frequency range of 1 Hz to 20 kHz.