Skip to main content

NONDESTRUCTIVE EVALUATION OF PLEXIGLAS MATERIALS USING LOCK-IN AND PULSE PHASE INFRARED THERMOGRAPHY

Roberto Montanini, Salvina Aliquò

Abstract

Lock-in and pulse phase infrared thermography measurement techniques have been exploited for quantitative assessment of subsurface defects in a reference specimen made of Plexiglas. Radiometric thermal images were post-processed using a contrast approach in the frequency domain, allowing defect depth location to be resolved with a relative combined standard uncertainty of about 7% for thicknesses above 3 mm. Conversely, significant radial heat diffusion next to the boundary of the discontinuity made accurate sizing of deeper subsurface defects more difficult. The obtained results demonstrate the potentiality of active thermography as a fast, powerful contactless NDT measurement tool.

Keywords
Temperature measurements, radiometric infrared thermography, non destructive testing (NDT)
Download
IMEKO-WC-2009-TC12-220.pdf
DOI
-
IMEKO TC
TC12 - Temperature and Thermal Measurements

Event details

Event
XIX IMEKO World Congress
Place
Lisbon, PORTUGAL
Time
6 September 2009 - 11 September 2009
Website
http://www.imeko2009.it.pt/

Back to the proceedings