Skip to main content

EVALUATION OF MEASUREMENT UNCERTAINTY FOR THE MOISTURE AND DRY MATTER MASS FRACTIONS IN INDUSTRIAL RESIDUES AND SLUDGES

Filomena C. Mouro, Sandra C. Calisto, Maria Ascensão Trancoso

Abstract

Moisture mass fraction, <i>w</i><sub>H<sub>2</sub>O</sub>, and dry matter mass fraction, <i>w</i><sub>DM</sub>, are analytical parameters required by environmental European regulations. The metrological quality, namely measurement uncertainty, comply the fitness for purpose and enhances the comparability of analytical results. In this work, the component by component approach for measurement uncertainty estimation of <i>w</i><sub>H<sub>2</sub>O</sub> and <i>w</i><sub>DM</sub> is reported and the input quantities assessed. The measurement uncertainty of method’s precision, under within-laboratory reproducibility conditions, <i>f</i>(precision)<sub>Rw</sub>, was the only significant influence quantity when <i>w</i><sub>H<sub>2</sub>O</sub> > 0,10 g g<sup>-1</sup> for both ranges. In case of <i>w</i><sub>H<sub>2</sub>O</sub> = 0,10 g g<sup>-1</sup>, the mass of the capsule containing sample after the drying step, <i>m</i><sub>(<i>C</i>+<i>S</i>)dry</sub>, has also a relevant contribution. Simplified models are proposed.

Keywords
uncertainty, moisture, dry matter, mass fraction
Download
IMEKO-WC-2009-TC24-533.pdf
DOI
-
IMEKO TC
TC24 - Chemical Measurements

Event details

Event
XIX IMEKO World Congress
Place
Lisbon, PORTUGAL
Time
6 September 2009 - 11 September 2009
Website
http://www.imeko2009.it.pt/

Back to the proceedings