At the Institute for Machine Elements and Machine Design three different escalator (moving staircase) gearboxes were tested to compare their coefficient of efficiency. The tested gears are two worm gears and a bevel-spur gear. The two worm gears differ in its tooth shape (hollow flank – involute flank).<BR />For this purpose a test bed consisting of gearbox, electric motor and regulated pendulum generator was built up.<BR />To calculate the coefficient of efficiency it is necessary to measure the input- and output-torque at both gear shafts. First is done by measuring the effective power (2- Wattmeter Method) of the electric motor. The second value, the output-torque, could be controlled with aid of the brake generator and is exactly known.<BR />The coefficient of efficiency of each gear is measured for both directions at idle, 25%, 40%, 50%, 75% and full load.

Keywords
gears, efficiency, coefficient of efficiency