Skip to main content

SENSITIVITY IMPROVEMENT IN PHASE NOISE MEASUREMENT

N. Majurec, R. Nagy, J. Bartolic

Abstract

An automated microwave phase noise measuring system with improved sensitivity is presented. The system is based on two oscillators measuring method. Improvement of sensitivity can be achieved by increasing the power applied to the RF input of the balanced mixer. However, in classical arrangement of the two oscillators method this is not possible due to already high power contained in the signal carrier. In the proposed measuring system, carrier is suppressed by the resonator. In that way, it is possible to significantly increase RF power from oscillator under test. The sensitivity improvement ranges from 20 to 40 dB.

Keywords
phase noise, measuring sensitivity
Download
IMEKO-WC-2000-TC4-P143.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
XVI IMEKO World Congress
Place
Vienna, AUSTRIA
Time
25 September 2000 - 28 September 2000

Back to the proceedings