The report is devoted to measurement problems of the capacitor parameters for superhigh capacitances (1 F-200 F). The models of such objects are proposed. The mechanism of influence on the measurement result is determined for additional parameters. These parameters are the absorption capacitance CA and the absorption resistance RA, the leakage resistance RL and the active serial resistance R. Besides, the measuring structures that make it possible to take into consideration the influence of additional parameters are proposed. Moreover, the accuracy of the proposed measuring structures is defined with the direct current and the alternating current.

Keywords
superhigh capacitance, absorption capacitance, leakage resistance
Download
IMEKO-WC-2000-TC4-P163.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
XVI IMEKO World Congress
Place
Vienna, AUSTRIA
Time
25 September 2000 - 28 September 2000