Skip to main content

ASSURING THE TRACEABILITY OF ELECTRONIC LEVELS FOR CALIBRATION OF GRANITE SURFACE PLATES

A. Gusel, B. Acko, A. Sostar

Abstract

Surface plates are used in the industry and measurement laboratories for performing measurements of length, angles and deviations of form and position of measured subjects, for checking and control of measurement bars and rulers. Our aim is to perform a calibration of the surface plate without involving either interferometric system or autocollimator, which would be too expensive, therefore using only electronic levels. And even when the appropriate device for calibration is chosen, the decision between many different types of algorithms has to be made. On top of all, traceability of measurement must be also assured. Research work in this field, represented in this article, is focused mainly on assuring the calibration traceability of results when performing measurements of flatness with electronic levels. Traceability is assured with accurate sine bar SL001, developed in our laboratory especially for purposes of very precise calibrations.

Keywords
flatness measurement, surface plates, traceability assurance
Download
IMEKO-WC-2000-TC8-P221.pdf
DOI
-
IMEKO TC
TC8 - Traceability in Metrology

Event details

Event
XVI IMEKO World Congress
Place
Vienna, AUSTRIA
Time
25 September 2000 - 28 September 2000

Back to the proceedings