Skip to main content

1 MHZ MODULE TRANSFORMER BRIDGE

M. D. Klionskiy

Abstract

A transformer bridge to study low-loss dielectrics at the frequency 1 MHz is developed. The main components of the bridge: a ratio transformer and variable measuring standards of capacitance and conductance are made in the form of removable modules. The bridge measurement range by loss angle tangent <i>D</i> is 10<sup>-6</sup> - 10<sup>-3</sup> with the capacitance 1-1000 pF. Measurement uncertainty <i>D</i> is &plusmn; (2-3) &itimes; 10<sup>-6</sup>, <i>k</i> = 2.

Keywords
transformer bridge, loss angle
Download
IMEKO-WC-2000-TC8-P222.pdf
DOI
-
IMEKO TC
TC8 - Traceability in Metrology

Event details

Event
XVI IMEKO World Congress
Place
Vienna, AUSTRIA
Time
25 September 2000 - 28 September 2000