CHARACTERIZATION OF THE PYROMETERS TO THE SUBJECT OF PREAMPLIFIER GAIN NONLINEARITY

Humbat Nasibov, Sevilay Ugur

Abstract

Dc-operated radiation thermometers, due to their high-speed response, simple and rigid optical and electrical systems are widely used in industry and science. Practically, in all metrology laboratories the realization and dissemination of the temperature scale (by means of radiation temperature) is carried out using the dc-operated transfer standard radiation thermometers. Therefore, the actuality of the accurate characterization of all aspects of the pyrometer system is evidently clear.<br /> This paper describes the systematic error contribution of the gain non-linearity of well-designed preamplifiers in the signal processing of the dc-operated radiation thermometers.

Keywords
radiation thermometer, preamplifier gain nonlinearity, noise equivalent temperature
Download
PWC-2003-TC12-028.pdf
DOI
-
IMEKO TC
TC12 - Temperature and Thermal Measurements

Event details

Event
XVII IMEKO World Congress
Place
Dubrovnik, CROATIA
Time
22 June 2003 - 28 June 2003
Website
http://www.hmd.hr/imeko/