IMPEDANCE METHOD FOR URBAN WATERWORKS: EXPERIMENTAL FREQUENCY ANALYSIS FOR LEAKAGE DETECTION

Aimé Lay-Ekuakille, Patrizia Vergallo, Amerigo Trotta

Abstract

Leakage detection methods are used to reveal liquid leaks in pipelines for many applications, namely, waterworks, oil pipelines, industry heat exchangers, etc.. The configuration of pipeline is a key issue because it impacts on the effectiveness of the method to be used and, consequently, on the results to be counterchecked. This paper proposes an improvement of impedance method for zigzag pipeline by carrying out an experimental frequency analysis that has been compared with other methods based on frequency response. Hence, impedance method is generally used for simple pipeline configurations because complicated pipelines with many curves introduce difficulties and major uncertainties in the calculation of characteristic impedance and in the statement of boundary conditions. The paper illustrates the case of a water pipeline where the leakage is acquired thanks to pressure transducers.

Download
IMEKO-TC19-2010-139.pdf
DOI
-
IMEKO TC
TC19 - Environmental Measurements

Event details

Event
Instrumentation for the Information and Communication Technology Era
Technical Committee
TC19
Place
Kosice, SLOVAKIA
Time
8 September 2010 - 10 September 2010
Website
http://www.imeko.tuke.sk

Back to the proceedings