Skip to main content

NON-LINEARITY DIAGNOSTICS FOR CONDUCTIVE ADHESIVES

Vaclav Papez, Stanislava Papezova

Abstract

The level of intermodulation products that are generated represents the extent of non-linearity for any electronic component. To determine the quality of connections with conductive adhesives the technique of evaluating non-linearity was used as a diagnostic method. The used measuring equipment is based on the evaluation of intermodulation distortion, which is generated by the non-linear component, when two sinusoidal signals are supplied. The equipment measures non-linearity of 3 orders. The measured level of non-linearity is -180 dB with respect to the actuating signal. The maximum current of the actuating signal is 2 x 2A, the sensitivity of the indicator is 10 nV.

Download
IMEKO-TC4-2010-015.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
Instrumentation for the Information and Communication Technology Era
Technical Committee
TC4
Place
Kosice, SLOVAKIA
Time
8 September 2010 - 10 September 2010
Website
http://www.imeko.tuke.sk

Back to the proceedings