Skip to main content

FIELD NON-UNIFORMITY OVER THE UNIFORM FIELD AREA AS PER IEC 61000-4-3 RADIATED IMMUNITY TEST

Carlo F. M. Carobbi, Giancarlo Borio, Domenico Festa, Andrea Zanobini

Abstract

The scope here is to quantify the non-uniformity of the electric field over the uniform field area as defined in the IEC 61000-4-3 standard for radiated immunity test. To this purpose the electric field intensity data over the 1.5 m x 1.5 m area, provided by nine laboratories, were collected and analysed. The frequency range considered is between 80 and 1000 MHz. It is shown that the non-uniformity is nearly frequency independent and amounts to 1.2 dB in terms of one standard deviation. This figure is meant to represent the average performance expected from a laboratory complying with the –0 to +6 dB field-uniformity requirement of the standard and is offered as a reference value useful for uncertainty evaluations.

Keywords
electromagnetic compatibility measurements, measurement uncertainty, radiated immunity, uniform field area
Download
IMEKO-TC4-2010-033.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
Instrumentation for the Information and Communication Technology Era
Technical Committee
TC4
Place
Kosice, SLOVAKIA
Time
8 September 2010 - 10 September 2010
Website
http://www.imeko.tuke.sk

Back to the proceedings