Skip to main content

AC STANDARD FOR ELECTRIC POWER QUALITY INDEXES CALIBRATOR

Sergiej Taranow, Yurij Tesyk, Oleh Karasinskij, Stanislava Pronseleva

Abstract

Transfer measurements from the standard of direct voltage to the standard of alternative voltage is widely used in measurement and instrumentation. Well known method is based on the usage of thermo converter of voltage. There are some drawbacks of this method such as instability of error, hand mode of calibration and inertia of reproduction process. The new method of reproduction AC (AV) value proposed by usage of inertia’s properties of links of the parallel-resonance circuit to transfer measurements from the standard of direct current to the standard of alternative current. The paper illustrates the mechanism of action of AC-calibrator based on proposed method of reproduction, where AC signal is coming through L-inductor without its changes.

Download
IMEKO-TC4-2010-060.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
Instrumentation for the Information and Communication Technology Era
Technical Committee
TC4
Place
Kosice, SLOVAKIA
Time
8 September 2010 - 10 September 2010
Website
http://www.imeko.tuke.sk