Skip to main content

Double quasi - balanced meter for measurement of inductor quality factor

Adam Cichy, Artur Skórkowski, Sebastian Barwinek

Abstract

A principle of operation and an implementation of a non – bridge quasi - balanced circuit designed to measure quality factor of real inductors has been presented in this paper. The circuit is based on well-known bridge circuit. A structural diagram describing the processing of signals has been presented. An implementation as a virtual instrument has been presented as well.

Keywords
quasi-balanced circuits, quality factor, virtual instruments
Download
IMEKO-TC4-2013-065.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
TC4 Symposium 2013
Technical Committee
TC4
Email
joaquin.del.rio@upc.edu