Skip to main content

COMPARISON OF THREE DIFFERENT SHUNTS DESIGN FOR AC-DC CURRENT TRANSFER

Lucas Di Lillo, Héctor Laiz, Eliana Yasuda, Ricardo García

Abstract

In order to update and improve INTI’s AC-DC current transfer capabilities, we developed three different types of 5 and 10 A shunts for the AC-DC current transfer measurements included in a new AC-DC Transfer Step-Up scheme. The construction details and the measurements results are described in this paper.

Keywords
AC-DC current transfer, current measurement, current shunts, thermal converters
Download
IMEKO-TC4-2011-015.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
TC4 Symposium 2011
Technical Committee
TC4
Email
eventos@metrologia.org.br
Place
Natal, BRAZIL
Time
27 September 2011 - 30 September 2011
Website
http://www.metrologia.org.br/metrologia2011/

Back to the proceedings