REALIZATION OF THE INDUCTANCE STANDARD AT CEM
Abstract
Inductance has been realized at Spanish Centre of Metrology (CEM) by means of a modified coaxial Maxwell-Wien bridge. This method ensures inductance traceability from the SI unit of capacitance and establishes the value of the CEM’s set of 10 mH standard inductors at the frequency of 1 kHz.
Event details
- Event
- TC4 Symposium 2011
- Technical Committee
- TC4
- eventos@metrologia.org.br
- Place
- Natal, BRAZIL
- Time
- 27 September 2011 - 30 September 2011
- Website
- http://www.metrologia.org.br/metrologia2011/