INMETRO’S PRIMARY AC-DC CURRENT TRANSFER STANDARD BASED ON PMJTCS
Abstract
This paper describes the new primary standard for the ac-dc current transfer at Inmetro, based on PMJTCs and the new shunts manufactured by Fluke for rated currents from 10 mA up to 20 A. The build-up of the ac-dc current scale is described together with the uncertainty budgets which result in final uncertainties at 5 A of 6 μA/A to 12 μA/A in the frequency range from 10 Hz to 100 kHz. These are small compared to international standards.
Event details
- Event
- TC4 Symposium 2011
- Technical Committee
- TC4
- eventos@metrologia.org.br
- Place
- Natal, BRAZIL
- Time
- 27 September 2011 - 30 September 2011
- Website
- http://www.metrologia.org.br/metrologia2011/