Skip to main content

INMETRO’S PRIMARY AND SECUNDARY MEASUREMENT STANDARD SYSTEMS FOR ZENER REFERENCES CALIBRATION

Regis P. Landim, Vitor Ferreira, Edson Afonso, Mariella Alzamora

Abstract

In this paper, the primary (Josephson-based) and secundary (Zener-based) measurement standard systems used for calibration of solid state voltage standards (Zeners) at Inmetro are described, as well as the calibration method, the related equations and uncertainty budgets.

Keywords
Josephson Voltage Standard system, measurement standards, Zener applications, Zener calibration
Download
IMEKO-TC4-2011-050.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
TC4 Symposium 2011
Technical Committee
TC4
Email
eventos@metrologia.org.br
Place
Natal, BRAZIL
Time
27 September 2011 - 30 September 2011
Website
http://www.metrologia.org.br/metrologia2011/

Back to the proceedings