Skip to main content

CRITICAL FLOW SONIC NOZZLES GAS FLOW FACILITY WITH MEDIUM-PRESSURE AND CLOSED-LOOP PIPELINES

Sun Lijun, Feng Qianqian, Li Shengjie, Tang Bing, Zhang Tao

Abstract

The requirement of gas flow facility with high pressure is increasing. But, the experiences of development the closed-loop high pressure facility are not enough. Critical flow sonic Nozzles gas flow facility with medium-pressure and Closed-Loop pipelines at Tianjin University Flow Lab was presented in the paper. The performance indexes, the flow loop, the uncertainty analysis of the facility were described. Discharge coefficient correction of nozzles at medium pressure and the flow rate stability control were shown in detail. The pressure of the facility is 0.3 ~ 1.6 MPa, the flow rate is 0.5 ~ 120 m<sup>3</sup>/h at working status, the uncertainty is better than 0.3% (<i>k</i> = 2).

Keywords
micro flow, leak rate, dilution method, capillary
Download
IMEKO-TC9-2013-027.pdf
DOI
-
IMEKO TC
TC9 - Flow Measurement

Event details

Event
FLOMEKO 2013
Technical Committee
TC9
Place
Paris, FRANCE
Time
24 September 2013 - 26 September 2013
Website
http://www.flomeko2013.fr