Skip to main content

CAVITATION OF LNG IN ULTRASONIC FLOWMETERS - CFD MODELLING

J. Sluše, J. Geršl

Abstract

In this paper a possible cavitation of LNG in ultrasonic flowmeters is investigated. The cavitation is an unwanted effect which can occur especially near the ultrasound transducer mountings where sharp edges at the wall can appear. By means of numerical modelling we predict pressure drops which can occur near the pockets in front of the ultrasound transducers. We then calculate a minimal sub-cooling of LNG below the bubble point temperature for which the cavitation can be avoided for various velocities and pressures in the fluid.

Keywords
LNG, flow meters,ultrasonic, cavitation, CFD modelling
Download
IMEKO-TC9-2013-066.pdf
DOI
-
IMEKO TC
TC9 - Flow Measurement

Event details

Event
FLOMEKO 2013
Technical Committee
TC9
Place
Paris, FRANCE
Time
24 September 2013 - 26 September 2013
Website
http://www.flomeko2013.fr

Back to the proceedings