ACCURACY ENHANCEMENT OF A COMBINED V/Z CLAMP-ON ULTRASONIC FLOW
Abstract
Ultrasonic flow metering with clamp-on type transducers is a promising method when portability in flow metering is necessary. Nevertheless, the clamp-on ultrasonic flow meter has low measurement accuracy as flow speed in the pipe decreases. If the two types of clamp-on ultrasonic flow paths, namely, Z-shaped and V-shaped ultrasonic paths, are combined, measurement accuracy can be increased because the metering output becomes robust. In the present study, the measurement accuracy of the combined clamp-on ultrasonic flow meter was within ±2 % at 50 m<sup>3</sup>/h, which was smaller than those of the Z-shaped and the V-shaped clamp-on ultrasonic flow meters at the same flow rate. This can provide an advantage for water resource management because a general guideline for the water resource management is less than ±2 %.
Event details
- Event
- FLOMEKO 2013
- Technical Committee
- TC9
- Place
- Paris, FRANCE
- Time
- 24 September 2013 - 26 September 2013
- Website