ORIFICE PLATES WITH DRAIN HOLES
Abstract
This paper presents new data and shows that the existing drain-hole equation in ISO/TR 15377 is unsatisfactory: it leads to flowrate errors up to nearly 2% in magnitude. The data on drain holes have a surprisingly strong dependence on the circumferential location of the pressure tappings. However, a new analysis takes this into account and has produced a formula for d’, the corrected orifice diameter taking account of the drain hole. It is very desirable to amend ISO/TR 15377:2007.
Event details
- Event
- FLOMEKO 2013
- Technical Committee
- TC9
- Place
- Paris, FRANCE
- Time
- 24 September 2013 - 26 September 2013
- Website
- http://www.flomeko2013.fr