Skip to main content

ORIFICE PLATES WITH DRAIN HOLES

Dr Michael Reader-Harris, David Addison

Abstract

This paper presents new data and shows that the existing drain-hole equation in ISO/TR 15377 is unsatisfactory: it leads to flowrate errors up to nearly 2% in magnitude. The data on drain holes have a surprisingly strong dependence on the circumferential location of the pressure tappings. However, a new analysis takes this into account and has produced a formula for d’, the corrected orifice diameter taking account of the drain hole. It is very desirable to amend ISO/TR 15377:2007.

Keywords
orifice plates, drain holes, ISO/TR 15377