Skip to main content

THREE-PHASE FLOW MEASUREMENT USING CORIOLIS MASS FLOW METERING

M. Henry, M. Tombs, F. Zhou, M. Zamora

Abstract

This paper describes a new three-phase flow metering technology, combining Coriolis mass flow and water cut readings and without applying any phase separation. The system has undergone formal laboratory trials at NEL, UK and at VNIIR, Kazan, Russia; a number of field trials have taken place in Russia. Results from the NEL trial will be described in detail. Initial experiences from field trials will also be described. Together, these results demonstrate the potential for using Coriolis mass flow metering combined with water cut metering for three-phase (oil/water/gas) measurement.

Keywords
three-phase metering, oil, water, gas, Coriolis, water cut readings
Download
IMEKO-TC9-2013-093.pdf
DOI
-
IMEKO TC
TC9 - Flow Measurement

Event details

Event
FLOMEKO 2013
Technical Committee
TC9
Place
Paris, FRANCE
Time
24 September 2013 - 26 September 2013
Website
http://www.flomeko2013.fr

Back to the proceedings