PERFORMANCE OF TURBINE FLOWMETER IN HORIZONTAL OIL-WATER FLOW
Abstract
The response of turbine flowmeter in horizontal oil-water two-phase flow is experimentally investigated. The flow patterns in pipe as well as the turbine behavior are captured via high speed videography. Varied incoming flow rates up to 30 m<sup>3</sup> d<sup>-1</sup> are tested. It is found that the turbine response in oil-water flow deflects from that in pure water. The deflection direction and extent depend on respective flow rates rather than flow pattern. Considerable deflection is only observed in stratified flow. In addition, a theoretical modeling of the response of turbine meter in steady stratified flow is realized. Preliminary tests indicate that the established model may predict some important features of meter response in reality.
Event details
- Event
- FLOMEKO 2013
- Technical Committee
- TC9
- Place
- Paris, FRANCE
- Time
- 24 September 2013 - 26 September 2013
- Website