Skip to main content

EXPERIMENTAL INVESTIGATION OF DISCHARGE COEFFICIENT AND TAPPING ERROR OF PTC 6 FLOW NOZZLE USING HIGH REYNOLDS NUMBER CALIBRATION RIG

N. Furuichi, K. H. Cheong, Y. Terao, S. Nakao, K. Fujita, K. Shibuya

Abstract

A tap effect of a discharge coefficient of a throat tap flow nozzle based on PTC 6 is investigated by measuring the discharge coefficient in 1.8 &times; 10<sup>5</sup> < <i>Re</i><sub>d</sub> < 1.4 &times; 10<sup>7</sup>. The measurement error of the differential pressure, when it is normalized by a wall shear stress including the effect of roughness caused by the hole of a tap, is described as a function of tap Reynolds number based on the friction velocity and the tap diameter. The equation of the discharge coefficient of the flow nozzle is proposed, which consists of the two terms that can be physically evaluated, the theoretical discharge coefficient and the measurement error of differential pressure.

Keywords
discharge coefficient, tapping error, PTC 6 flow nozzle, high Reynolds number, calibration
Download
IMEKO-TC9-2013-106.pdf
DOI
-
IMEKO TC
TC9 - Flow Measurement

Event details

Event
FLOMEKO 2013
Technical Committee
TC9
Place
Paris, FRANCE
Time
24 September 2013 - 26 September 2013
Website
http://www.flomeko2013.fr

Back to the proceedings