Skip to main content

Remote Field Eddy Current NDT in Tubes Using Anisotropic Magneto-Resistors

D. J. Pasadas, A. Lopes Ribeiro, T. J. Rocha, H. G. Ramos

Abstract

This paper presents a measuring system capable of detecting longitudinal and circumferential defects using remote field eddy current in stainless steel tubes with an AMR sensor. An excitation coil is required with a time varying current to produce a magnetic field that penetrates the material on test. The experimental results from both defects are compared with other results for the same material without any defect. The obtained results represent the AMR output magnetic field amplitude and the phase difference between the magnetic field produced by the excitation coil and the magnetic field measured by the AMR sensor. The paper also presents the defect signature for each defect.

Download
IMEKO-TC10-2014-010.pdf
DOI
-
IMEKO TC
TC10 - Measurement for Diagnostics, Optimization and Control

Event details

Event
TC10 Workshop on Technical Diagnostics 2014
Technical Committee
TC10
Place
Warsaw, POLAND
Time
26 June 2014 - 27 June 2014
Website
http://imekotc10-2014.org/

Back to the proceedings