The problem of obtaining the difference of two AC voltages represented by vectors with arbitrary amplitude and phase at accuracy levels unattainable with electronic amplifiers is addressed. A solution consisting in a precision complex transformer is presented, together with a mathematical model and some preliminary studies of more general interest. A shielded prototype has performed accuracy levels below 1 &times; 10<sup>-6</sup> from 30 Hz to 12 kHz and a common-mode rejection ratio exceeding 140 dB from 800 Hz to 40 KHz.