Skip to main content

IMPROVING VORTEX FLOW METERING USING ULTRASOUND

Volker Hans, Christian Filips

Abstract

Commercial vortex flowmeters use the well-known effect of Karman vortex street. The frequency of vortices generated in the wake of a bluff body is proportional to the average flow velocity. Usually it is detected by pressure sensors which are not very sensitive. Therefore bluff bodies of big sizes are required. An alternative method to detect the vortices in the streaming fluid is to use a high sensitive ultrasonic wave which is complex modulated. The demodulation can be executed by digital signal processing. Small sizes of bluff bodies can be realized. The bluff body size and the carrier frequency must be harmonized.

Keywords
vortex flowmeters, ultrasound, bluff body geometry
Download
IMEKO-TC9-2003-036.pdf
DOI
-
IMEKO TC
TC9 - Flow Measurement

Event details

Event
FLOMEKO 2003
Technical Committee
TC9
Place
Groningen, NETHERLANDS
Time
12 May 2003 - 14 May 2003
Website
www.flomeko2003.nl

Back to the proceedings