Skip to main content

CHARACTERISTICS OF SMALL SONIC NOZZLES

K. A Park, Y. M. Choi, H. M. Choi, T. S. Cha, B. H. Yoon

Abstract

Small sonic nozzles (throat diameter 0.28 4.48 mm) were tested in the gas flow standard system. This standard system is composed of two bell provers and 5 column piston provers, compressor, filters, and dehumidifier. The discharge coefficients of small sonic nozzles are obtained and correlated as a function of throat Reynolds numbers with 0.33 % uncertainty at a confidence level 95 %. The tested high Reynolds number was the lower limit of ISO 9300 specifications. The data are useful as data base for revision of ISO 9300.

Keywords
sonic nozzle, throat diameter, discharge coefficient
Download
IMEKO-TC9-2000-060.pdf
DOI
-
IMEKO TC
TC9 - Flow Measurement

Event details

Event
FLOMEKO 2000
Technical Committee
TC9
Place
Salvador, Bahia, BRAZIL
Time
4 June 2000 - 8 June 2000

Back to the proceedings