Skip to main content

PIEZOELECTRIC SENSITIVITY MEASUREMENTS OF CELLULOSE NANOFIBRIL SENSORS

Satu Rajala, Maija Vuoriluoto, Orlando J. Rojas, Sami Franssila, Sampo Tuukkanen

Abstract

Piezoelectric sensitivity of cellulose nanofibril (CNF) film sensors was measured using a mechanical shaker and charge amplifier setup. In-house fabricated CNF film sensors showed 5-7 pC/N sensitivity in ambient conditions. The CNF film used here contained randomly oriented fibrils, and the piezoelectric response is expected to increase remarkably after film polarization and fibril alignment. The results obtained in this study suggest that nanocellulose film is a suitable sensor material for applications in various fields such as material sciences, electronics and biomedical diagnostics.

Keywords
cellulose nanofibrils, piezoelectric sensors, sensitivity measurement
Download
IMEKO-WC-2015-TC3-086.pdf
DOI
-
IMEKO TC
TC3 - Measurement of Force, Mass, Torque, and Gravity

Event details

Event
XXI IMEKO World Congress
Place
Prague, CZECH REPUBLIC
Time
30 August 2015 - 4 September 2015
Website
http://imeko2015.org/

Back to the proceedings