Skip to main content

MEASUREMENT OF THE CURRENT TRANSFER RATIO FOR CURRENT SHUNTS

Pavel F. Baranov, Edvard I. Tsimbalist, Valeriy N. Borikov, Diana G. Soltanova

Abstract

Current shunts are widely used in metrological practice. The shunt is required to determine the value of its resistance on DC and AC currents to determine the transfer ratio error in the wide frequency band in process calibration. The paper describes a procedure for measuring the complex impedance of transfer ratio of current shunts in the frequency band using the lock-in amplifier with the differential input. The experimental results of the proposed procedure are described.

Keywords
current shunt, lock-in amplifier, transfer ratio, calibration, complex impedance
Download
IMEKO-WC-2015-TC4-102.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
XXI IMEKO World Congress
Place
Prague, CZECH REPUBLIC
Time
30 August 2015 - 4 September 2015
Website
http://imeko2015.org/

Back to the proceedings