Skip to main content

PERFORMANCE OF THE STRETCHED- AND VIBRATING-WIRE TECHNIQUES AND CORRECTION OF BACKGROUND FIELDS IN LOCATING QUADRUPOLE MAGNETIC AXES

Pasquale Arpaia, Domenico Caiazza, Carlo Petrone, Stephan Russenschuck

Abstract

A single conducting wire is used for localizing the magnetic axis of a quadrupole magnet. The localization is performed by both the stretched-wire and the vibrating-wire method. The compatibility of the two measurements is demonstrated and the measurement repeatability is assessed for both the methods at varying the magnet gradient. Furthermore, the influence of the background magnetic field in the two approaches is studied at varying the magnetic field strength. Experimental results are given for a normal-conducting quadrupole magnet.

Keywords
stretched wire, vibrating wire, magnetic axis, magnetic measurement
Download
IMEKO-WC-2015-TC4-105.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
XXI IMEKO World Congress
Place
Prague, CZECH REPUBLIC
Time
30 August 2015 - 4 September 2015
Website
http://imeko2015.org/

Back to the proceedings