Skip to main content

FREQUENCY RESPONSE OF SELECTED CURRENT TRANSFORMES AND HALL-EFFECT CURRENT SENSORS

Richard Schreiber, Iveta Sikorová

Abstract

This paper is dealing with the comparison of isolated current sensors of nominal value up to 200 A. Emphasis is placed on the operation of the sensors at very low frequencies, where the amplitude and phase error is evaluated. This research was needed for the choice of an optimal current sensor for the development of a diagnostic system for induction motors. The most suitable sensors in the terms of performance and cost are selected in accordance with the application.

Keywords
current sensors, current transformer, Hall-effect current sensor, transfer function measurement, comparison
Download
IMEKO-WC-2015-TC4-151.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
XXI IMEKO World Congress
Place
Prague, CZECH REPUBLIC
Time
30 August 2015 - 4 September 2015
Website
http://imeko2015.org/

Back to the proceedings