Skip to main content

MEASUREMENT OF METHANE CALORIFIC VALUE USING METAL JACKET BURNER

Joohyun Lee, Suyong Kwon, Yong-Gyoo Kim

Abstract

Reference gas calorimeter was built based on the isoperibolic method. Unlike the other reference gas burner which is usually made of glass, the developed gas burner was made of stainless steel and gross calorific value of methane was measured. The result shows 0.4% difference with the value specified by ISO 6976 and the uncertainty is 1.1%. The metal jacket burner shows the promise of the standardization of the gas burner and development of the portable device.

Keywords
calorimeter, calorific value, gas burner, methane, metal burner
Download
IMEKO-WC-2015-TC12-255.pdf
DOI
-
IMEKO TC
TC12 - Temperature and Thermal Measurements

Event details

Event
XXI IMEKO World Congress
Place
Prague, CZECH REPUBLIC
Time
30 August 2015 - 4 September 2015
Website
http://imeko2015.org/

Back to the proceedings