Skip to main content

UNEQUALIZED CURRENTS IN TWO TERMINAL-PAIR COAXIAL CAPACITANCE BRIDGES

G.A. Kyriazis, R.T.B. Vasconcellos, J. Melcher

Abstract

It is necessary to maintain conditions of zero net currents in the cables of ac coaxial bridges. Current equalizers are used for dealing with this problem. It is shown here how they were applied in the construction of a two terminal-pair capacitance bridge with an uncertainty of about one part in 10<sup>8</sup>.

Keywords
current equalizers, unequalized currents, coaxial bridges
Download
PWC-2006-TC4-048u.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
XVIII IMEKO World Congress
Place
Rio de Janeiro, BRAZIL
Time
17 September 2006 - 22 September 2006
Website
http://www.metrologia2006.org.br

Back to the proceedings