Skip to main content

Non destructive tests to detect the integrity of steel anchors in corrosive environments

Luigi Ferrigno, Giuseppe Modoni, Giovanni Betta, Paolo Croce, Erminio Salvatore

Abstract

Metal-tensioned systems like bar or strand anchors may lose efficiency and eventually reach failure due to corrosion caused by aggressive ground condi tions or stray currents. Early recognition tests capable of highlighting the loss of performance would enable to undertake remediation before these effects become catastrophic. The paper analyses the efficiency of different non-invasive techniques adopted to assess the continui ty and the geometric shrinkage of metal bars. A review of the literature is initially made to illustrate potentials and defects of the different solutions providing a one-dimensional propagation of waves along slender elements. Then an experimental set-up is created in the laboratory to evaluate the effectiveness of a ultrasonic vibratory wave system wi th bench tests on bars of various geometrical and mechanical characteristics. Defects such as cross sectional reduction, artificially simulated on the bars, are highlighted by the analyses of the recorded signals .

Keywords
Ultrasonic Waves, Control, Anchors, Corrosion
Download
IMEKO-TC4-GEO-2016-39.pdf
DOI
-
IMEKO TC
TC4 - Measurement of Electrical Quantities

Event details

Event
TC4 International Workshop on Metrology for Geotechnics 2016
Technical Committee
TC4
Email
daponte@unisannio.it
Place
Benevento, ITALY
Time
17 March 2016 - 18 March 2016

Back to the proceedings