Air Density Determination By Using Buoyancy Artefacts at SASO NMCC
Abstract
In this study, the air density has been determined with relative uncertainty of 1,75 × 10<sup>-5</sup> (<i>k</i> = 1) by using experimental method to establish SASO NMCC’s mass scale at the highest accuracy. Hollow and tabular type buoyancy artefacts, which have the same surface area, but a different volume of 279, 1196 cm<sup>3</sup>, have been compared under the vacuum of 5 × 10<sup>-6</sup> mbar and in air by using 1 kg vacuum mass comparator.
Event details
- Event
- tc3-2017